Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 783
Filtrar
1.
Mikrochim Acta ; 191(5): 247, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587580

RESUMO

Alumina inorganic molecularly imprinted polymer (MIP) modified multi-walled carbon nanotubes (MWCNTs) on a glassy carbon electrode (MWCNTs-Al2O3-MIP/GCE) was firstly designed and fabricated by one-step electro deposition technique for the detection of uric acid (UA) in sweat. The UA templates were embedded within the inorganic MIP by co-deposition with Al2O3. Through the evaluation of morphology and structure by Field Emission Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), X-ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM), it was verified that the specific recognition sites can be fabricated in the electrodeposited Al2O3 molecular imprinted layer. Due to the high selectivity of molecular imprinting holes, the MWCNTs-Al2O3-MIP/GCE electrode demonstrated an impressive imprinting factor of approximately 2.338 compared to the non-molecularly imprinted glassy carbon electrode (MWCNTs-Al2O3-NIP/GCE) toward uric acid detection. Moreover, it exhibited a remarkable limit of detection (LOD) of 50 nM for UA with wide detection range from 50 nM to 600 µM. The MWCNTs-Al2O3-MIP/GCE electrode also showed strong interference resistance against common substances found in sweat. These results highlight the excellent interference resistance and selectivity of MWCNTs-Al2O3-MIP/GCE sensor, positioning it as a novel sensing platform for non-invasive uric acid detection in human sweat.


Assuntos
Nanotubos de Carbono , Fosfatos , Suor , Humanos , Polímeros Molecularmente Impressos , Ácido Úrico , Óxido de Alumínio
2.
Mikrochim Acta ; 191(5): 253, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592400

RESUMO

The development of distance-based paper analytical devices (dPADs) integrated with molecularly imprinted polymers (MIPs) to monitor Escherichia coli (E. coli) levels in food samples is presented. The fluidic workflow on the device is controlled using a designed hydrophilic bridge valve. Dopamine serves as a monomer for the formation of the E. coli-selective MIP layer on the dPADs. The detection principle relies on the inhibition of the E. coli toward copper (II) (Cu2+)-triggered oxidation of o-phenylenediamine (OPD) on the paper substrate. Quantitative detection is simply determined through visual observation of the residual yellow color of the OPD in the detection zone, which is proportional to E. coli concentration. The sensing exhibits a linear range from 25.0 to 1200.0 CFU mL-1 (R2 = 0.9992) and a detection limit (LOD) of 25.0 CFU mL-1 for E. coli detection. Additionally, the technique is highly selective with no interference even from the molecules that have shown to react with OPD to form oxidized OPD. The developed device demonstrates accuracy and precision for E. coli quantification in food samples with recovery percentages between 98.3 and 104.7% and the highest relative standard deviation (RSD) of 4.55%. T-test validation shows no significant difference in E. coli concentration measured between our method and a commercial assay. The proposed dPAD sensor has the potential for selective and affordable E. coli determination  in food samples without requiring sample preparation. Furthermore, this strategy can be extended to monitor other molecules for which MIP can be developed and integrated into paper-microfluidic platform.


Assuntos
Escherichia coli , Fenilenodiaminas , Polímeros , Polímeros Molecularmente Impressos , Bioensaio
3.
Biosens Bioelectron ; 255: 116269, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579624

RESUMO

Saxitoxin (STX), which is produced by certain dinoflagellate species, is a type of paralytic shellfish poisoning toxin that poses a serious threat to human health and the environment. Therefore, developing a technology for the convenient and cost-effective detection of STX is imperative. In this study, we developed an affinity peptide-imprinted polymer-based indirect competitive ELISA (ic-ELISA) without using enzyme-toxin conjugates. AuNP/Co3O4@Mg/Al cLDH was synthesized by calcining AuNP/ZIF-67@Mg/Al LDH, which was obtained by combining AuNPs, ZIF-67, and flower-like Mg/Al LDH. This synthesized nanozyme exhibited high catalytic activity (Km = 0.24 mM for TMB and 132.5 mM for H2O2). The affinity peptide-imprinted polymer (MIP) was imprinted with an STX-specific template peptide (STX MIP) on a multi-well microplate and then reacted with an STX-specific signal peptide (STX SP). The interaction between the STX SP and MIP was detected using a streptavidin-coated nanozyme (SA-AuNP/Co3O4@Mg/Al cLDH). The developed MIP-based ic-ELISA exhibited excellent selectivity and sensitivity, with a limit of detection of 3.17 ng/mL (equivalent: 0.317 µg/g). Furthermore, the system was validated using a commercial ELISA kit and mussel tissue samples, and it demonstrated a high STX recovery with a low coefficient of variation. These results imply that the developed ic-ELISA can be used to detect STX in real samples.


Assuntos
Técnicas Biossensoriais , Cobalto , Nanopartículas Metálicas , Óxidos , Humanos , Toxinas Marinhas/análise , Polímeros Molecularmente Impressos , Ouro , Peróxido de Hidrogênio , Frutos do Mar/análise , Saxitoxina , Ensaio de Imunoadsorção Enzimática/métodos , Peptídeos , Polímeros
4.
Molecules ; 29(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38611955

RESUMO

Lumpy Skin Disease (LSD) is a notifiable viral disease caused by Lumpy Skin Disease virus (LSDV). It is usually associated with high economic losses, including a loss of productivity, infertility, and death. LSDV shares genetic and antigenic similarities with Sheep pox virus (SPV) and Goat pox (GPV) virus. Hence, the LSDV traditional diagnostic tools faced many limitations regarding sensitivity, specificity, and cross-reactivity. Herein, we fabricated a paper-based turn-on fluorescent Molecularly Imprinted Polymer (MIP) sensor for the rapid detection of LSDV. The LSDV-MIPs sensor showed strong fluorescent intensity signal enhancement in response to the presence of the virus within minutes. Our sensor showed a limit of detection of 101 log10 TCID50/mL. Moreover, it showed significantly higher specificity to LSDV relative to other viruses, especially SPV. To our knowledge, this is the first record of a paper-based rapid detection test for LSDV depending on fluorescent turn-on behavior.


Assuntos
Vírus da Doença Nodular Cutânea , Animais , Bovinos , Ovinos , Polímeros Molecularmente Impressos , Corantes , Reações Cruzadas , Cabeça
5.
J Hazard Mater ; 470: 134218, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38581878

RESUMO

The development of high-performance sensors for doxycycline (DOX) detection is necessary because its residue accumulation will cause serious harm to human health and the environment. Here, a novel tri-emission ratiometric fluorescence sensor was proposed by using "post-mixing" strategy of different emissions fluorescence molecularly imprinted polymers with salicylamide as dummy template (DMIPs). BSA was chosen as assistant functional monomer, and also acted as sensitizers for the aggregation-induced emission (AIE) effect of DOX. The blue-emitting carbon dots and the red-emitting CdTe quantum dots were separately introduced into DMIPs as the response signals. Upon DOX recognition within 2 min, blue and red fluorescence of the tri-emission DMIPs sensor were quenched while green fluorescence of DOX was enhanced, resulting in a wide range of color variations observed over bluish violet-rosered-light pink-orange-yellow-green with a detection limit of 0.061 µM. The sensor possessed highly selective recognition and was successfully applied to detect DOX in complicated real samples. Moreover, with the fluorescent color collection and data processing, the smartphone-assisted visual detection of the sensors showed satisfied sensitivity with low detection limit. This work provides great potential applications for rapid and visual detection of antibiotics in complex substrates.


Assuntos
Antibacterianos , Compostos de Cádmio , Doxiciclina , Impressão Molecular , Pontos Quânticos , Espectrometria de Fluorescência , Telúrio , Doxiciclina/análise , Doxiciclina/química , Pontos Quânticos/química , Telúrio/química , Antibacterianos/análise , Compostos de Cádmio/química , Limite de Detecção , Fluorescência , Carbono/química , Corantes Fluorescentes/química , Polímeros Molecularmente Impressos/química , Smartphone
6.
Mikrochim Acta ; 191(5): 269, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630309

RESUMO

A molecularly-imprinted electrochemiluminescence sensor was constructed for the determination of fenpropathrin (FPT) by molecular imprinting technology. In this sensing platform, the introduction of CdS@MWCNTs significantly enhanced the initial ECL signal of the luminol-O2 system. Specifically, MWCNTs was used as a carrier to adsorb more CdS, in which CdS acted as a co-reaction promoter for luminescence. Molecularly imprinted polymer (MIP) containing specific recognition sites of FPT was used as the material for selective recognition. With increasing amount of FPT the ECL signal decreased. Under the optimum conditions, the ECL response was linearly related to the logarithm of FPT concentration. The developed ECL sensor allowed for sensitive determination of FPT and exhibited a wide linear range from 1.0 × 10- 10 mol L- 1 to 1.0 × 10- 6 mol L- 1. The limit of detection was 3.3 × 10- 11 mol L- 1 (S/N = 3). It can be used for the detection of FPT in vegetable samples.


Assuntos
Luminescência , Impressão Molecular , Piretrinas , Luminol , Polímeros Molecularmente Impressos
7.
Mikrochim Acta ; 191(5): 270, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630200

RESUMO

A comparative analysis of molecularly imprinted polymers based on different synthesis techniques was performed for the recognition of molnupiravir (MOL). The polymerizations were performed with 3-thienyl boronic acid (3-TBA) as a functional monomer by electropolymerization (EP) and with guanine methacrylate (GuaM) as a functional monomer by photopolymerization (PP). Morphological and electrochemical characterizations of the developed sensors were investigated to verify the constructed sensors. Moreover, quantum chemical calculations were used to evaluate changes on the electrode surface at the molecular and electronic levels. The dynamic linear range of both designed sensors under optimized experimental conditions was found to be 7.5 × 10-12-2.5 × 10-10 M and 7.5 × 10-13-2.5 × 10-11 M for EP and PP, respectively. The effect of various interfering agents on MOL peak current was assessed for the selectivity of the study. In the presence of 100 times more interfering agents, the RSD and recovery values were determined. The RSD values of GuaM/MOL@MIP/GCE and poly(Py-co-3-PBA)/MOL@MIP/GCE sensors were found to be 1.99% and 1.72%, respectively. Furthermore, the recovery values of the MIP-based sensors were 98.18-102.69% and 98.05-103.72%, respectively. In addition, the relative selectivity coefficient (k') of the proposed sensor was evaluated, and it exhibited good selectivity for MOL with respect to the NIP sensor. The prepared sensor was successfully applied to determine MOL in commercial serum samples and capsule form. In conclusion, the developed sensors provided excellent reproducibility, repeatability, high sensitivity, and selectivity against the MOL molecule.


Assuntos
Ácidos Borônicos , Citidina/análogos & derivados , Hidroxilaminas , Polímeros Molecularmente Impressos , Reprodutibilidade dos Testes , Eletrodos , Guanina , Metacrilatos
8.
Mikrochim Acta ; 191(5): 242, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573524

RESUMO

Molecularly imprinted polymer (MIP) nanofilms for alpha-fetoprotein (AFP) and the receptor binding domain (RBD) of the spike protein of SARS-CoV-2 using either a peptide (epitope-MIP) or the whole protein (protein-MIP) as the template were prepared by electropolymerization of scopoletin. Conducting atomic force microscopy revealed after template removal and electrochemical deposition of gold a larger surface density of imprinted cavities for the epitope-imprinted polymers than when using the whole protein as template. However, comparable affinities towards the respective target protein (AFP and RBD) were obtained for both types of MIPs as expressed by the KD values in the lower nanomolar range. On the other hand, while the cross reactivity of both protein-MIPs towards human serum albumin (HSA) amounts to around 50% in the saturation region, the nonspecific binding to the respective epitope-MIPs is as low as that for the non-imprinted polymer (NIP). This effect might be caused by the different sizes of the imprinted cavities. Thus, in addition to the lower costs the reduced nonspecific binding is an advantage of epitope-imprinted polymers for the recognition of proteins.


Assuntos
COVID-19 , alfa-Fetoproteínas , Humanos , SARS-CoV-2 , Epitopos , Polímeros Molecularmente Impressos , Polímeros
9.
Biosensors (Basel) ; 14(3)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38534228

RESUMO

Development of an efficient technique for accurate and sensitive dibutyl phthalate (DBP) determination is crucial for food safety and environment protection. An ultrasensitive molecularly imprinted polymers (MIP) voltammetric sensor was herein engineered for the specific determination of DBP using poly-l-lysine/poly(3,4-ethylenedioxythiophene)/porous graphene nanocomposite (PLL/PEDOT-PG) and poly(o-phenylenediamine)-imprinted film as a label-free and sensing platform. Fabrication of PEDOT-PG nanocomposites was achieved through a simple liquid-liquid interfacial polymerization. Subsequently, poly-l-lysine (PLL) functionalization was employed to enhance the dispersibility and stability of the prepared PEDOT-PG, as well as promote its adhesion on the sensor surface. In the presence of DBP, the imprinted poly(o-phenylenediamine) film was formed on the surface of PLL/PEDOT-PG. Investigation of the physical properties and electrochemical behavior of the MIP/PLL/PEDOT-PG indicates that the incorporation of PG into PEDOT, with PLL uniformly wrapping its surface, significantly enhanced conductivity, carrier mobility, stability, and provided a larger surface area for specific recognition sites. Under optimal experimental conditions, the electrochemical response exhibited a linear relationship with a logarithm of DBP concentration within the range of 1 fM to 5 µM, with the detection limit as low as 0.88 fM. The method demonstrated exceptional stability and repeatability and has been successfully applied to quantify DBP in plastic packaging materials.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Grafite , Impressão Molecular , Nanocompostos , Fenilenodiaminas , Polímeros , Dibutilftalato , Polímeros Molecularmente Impressos , Técnicas Eletroquímicas/métodos , Grafite/química , Polilisina , Porosidade , Nanocompostos/química , Impressão Molecular/métodos , Limite de Detecção , Eletrodos
10.
Anal Bioanal Chem ; 416(10): 2479-2492, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38462592

RESUMO

Bisphenol A (BPA), known for its endocrine-disrupting properties and potential to leach into food products, has led to significant food safety concerns. Therefore, the development of sensitive and selective BPA rapid detection methods is crucial. In this study, molecularly imprinted solid-phase extraction coupled to a colorimetric method was adopted for the smartphone-based determination of BPA. The molecularly imprinted polymer (MIP) was prepared via photopolymerization and used as a selective adsorbent material for SPE columns. The solid-phase extraction (SPE) columns with multiple cycles significantly reduced the extraction time to only 30 min. The developed method demonstrates useful sensitivity for BPA (LOD = 30 ppb). Furthermore, BPA migration from plastic packaging was evaluated under different storage conditions, revealing that microwave treatment for 5 min led to BPA release from polycarbonate packaging in juice and basic solutions. The MIP selective extraction/clean-up and smartphone-based optical sensor were successfully applied to BPA standard solutions and complex food samples (e.g., juice and tap water), resulting in reproducible and selective BPA determination (RSD ≤ 6%, n = 3). This rapid and cost-effective method of producing MIPs for BPA offers a promising solution for fast and low-cost sensing for on-site fresh food analysis.


Assuntos
Impressão Molecular , Fenóis , Impressão Molecular/métodos , Smartphone , Extração em Fase Sólida/métodos , Água , Compostos Benzidrílicos/análise , Polímeros Molecularmente Impressos
11.
Toxins (Basel) ; 16(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38535785

RESUMO

Magnetic molecularly imprinted polymers (MMIPs) have fused molecular imprinting technology with magnetic separation technology, emerging as an innovative material capable of recognizing specific molecules and efficiently separating target substances. Their application to the extraction and purification of mycotoxins has great potential, due to the toxicity and economic impact of these contaminants. In this work, MMIP has been proposed as a sample treatment for the determination of main four aflatoxins (B1, B2, G1 and G2) in pig feed. The MMIP was formed through the integration of magnetic material (Fe3O4) with commercial molecularly imprinted polymers, avoiding the synthesis step and, therefore, simplifying the process. The analyses were carried out by high-performance liquid chromatography with fluorescence detection and the method was validated and limits of quantification (LOQs) between 0.09 and 0.47 ng/g were obtained, below the allowed or recommended levels by the European Union. Repeatability and intermediate precision showed relative standard deviations lower than 10% in all cases and trueness ranged from 92 to 111%. Finally, the proposed method was applied to 31 real pig feed samples, detecting aflatoxins with concentrations between 0.2 and 3.2 ng/g.


Assuntos
Aflatoxinas , Micotoxinas , Animais , Suínos , Polímeros Molecularmente Impressos , Cromatografia Líquida de Alta Pressão , União Europeia
12.
Biosens Bioelectron ; 254: 116201, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38507928

RESUMO

Developing highly sensitive and selective methods that incorporate specific recognition elements is crucial for detecting small molecules because of the limited availability of small molecule antibodies and the challenges in obtaining sensitive signals. In this study, a generalizable photoelectrochemical-colorimetric dual-mode sensing platform was constructed based on the synergistic effects of a molecularly imprinted polymer (MIP)-aptamer sandwich structure and nanoenzymes. The MIP functionalized peroxidase-like Fe3O4 (Fe3O4@MIPs) and alkaline phosphatase mimic Zr-MOF labeled aptamer (Zr-mof@Apt) were used as the recognition elements. By selectively accumulating dibutyl phthalate (DBP), a small molecule target model, on Fe3O4@MIPs, the formation of Zr-MOF@Apt-DBP- Fe3O4@MIPs sandwich structure was triggered. Fe3O4@MIPs oxidized TMB to form blue-colored oxTMB. However, upon selective accumulation of DBP, the catalytic activity of Fe3O4@MIPs was inhibited, resulting in a lighter color that was detectable by the colorimetric method. Additionally, Zr-mof@Apt effectively catalyzed the hydrolysis of L-Ascorbic acid 2-phosphate sesquimagnesium salt hydrate (AAPS), generating ascorbic acid (AA) that could neutralize the photogenerated holes to decrease the photocurrent signals for PEC sensing and reduce oxTMB for colorimetric testing. The dual-mode platform showed strong linearity for different concentrations of DBP from 1.0 pM to 10 µM (PEC) and 0.1 nM to 0.5 µM (colorimetry). The detection limits were 0.263 nM (PEC) and 30.1 nM (colorimetry) (S/N = 3), respectively. The integration of dual-signal measurement mode and sandwich recognition strategy provided a sensitive and accurate platform for the detection of small molecules.


Assuntos
Técnicas Biossensoriais , Polímeros Molecularmente Impressos , Colorimetria/métodos , Peroxidase/química , Peroxidases
13.
Food Chem ; 446: 138839, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38428083

RESUMO

α-Dicarbonyl compounds (α-DCs) are important intermediates and precursors of harmful Maillard reaction products (e.g., acrylamide and late glycosylation end-products), and they exist widely in thermoprocessed sugar- or fat-rich foods. α-DCs and their end-products are prone to accumulation in the human body and lead to the development of various chronic diseases. Therefore, detection of α-DCs and their associated hazards in food samples is crucial. This paper reviews the preparation of molecularly imprinted polymers (MIPs) enabling visual intelligent responses and the strategies for recognition and capture of α-DCs and their associated hazards, and provides a comprehensive summary of the development of visual MIPs, including integration strategies and applications with real food samples. The visual signal responses as well as the mechanisms for hazard recognition and capture are highlighted. Current challenges and prospects for visual MIPs with advanced applications in food, agricultural and environmental samples are also discussed. This review will open new horizons regarding visual MIPs for recognition and inhibition of hazards in food safety.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Humanos , Polímeros , Inocuidade dos Alimentos , Produtos Finais de Glicação Avançada
14.
Talanta ; 273: 125883, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38521023

RESUMO

Quercetin (QUE) is a powerful antioxidant and one of the common phenolic compounds found in plants, vegetables, and fruits, which has shown many pharmacological activities. The complex nature of the matrix in which QUE is found and its importance and potential uses in diverse applications force the researchers to develop selective and sensitive sensors. In the present work, a novel molecularly imprinted polymer (MIP)-based electrochemical sensor was fabricated for the selective and sensitive determination of the QUE in plant extracts and food supplements. Tryptophan methacrylate (TrpMA) was chosen as the functional monomer, whereas the photopolymerization (PP) method was applied using a glassy carbon electrode (GCE). Electrochemical and morphological characterizations of the developed sensor (TrpMA@QUE/MIP-GCE) were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). The linear range of the developed sensor was determined to be in the range of 1.0-25 pM, while the limit of detection (LOD) was calculated to be 0.235 pM. In conclusion, The TrpMA@QUE/MIP-GCE sensor might be classified as a promising platform for selective and sensitive determination of QUE not only in plant extracts but also in commercial food supplements because of its reliability, reproducibility, repeatability, stability, and fast response time.


Assuntos
Fragaria , Impressão Molecular , Rubus , Polímeros/química , Quercetina , Reprodutibilidade dos Testes , Metanol , Técnicas Eletroquímicas/métodos , Carbono/química , Limite de Detecção , Polímeros Molecularmente Impressos , Eletrodos , Extratos Vegetais
15.
Lab Chip ; 24(8): 2262-2271, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38501606

RESUMO

This article introduces distance-based paper analytical devices (dPADs) integrated with molecularly imprinted polymers (MIPs) and carbon dots (CDs) for simultaneous quantification of cytokine biomarkers, namely C-reactive protein (CRP), tumor necrosis factor-alpha (TNF-α), and interleukin-6 (IL-6) in human biological samples for diagnosis of cytokine syndrome. Using fluorescent CDs and MIP technology, the dPAD exhibits high selectivity and sensitivity. Detection is based on fluorescence quenching of CDs achieved through the interaction of the target analytes with the MIP layer on the paper substrate. Quantitative analysis is easily accomplished by measuring the distance length of quenched fluorescence with a traditional ruler and naked eye readout enabling rapid diagnosis of cytokine syndrome and the underlying infection. Our sensor demonstrated linear ranges of 2.50-24.0 pg mL-1 (R2 = 0.9974), 0.25-3.20 pg mL-1 (R2 = 0.9985), and 1.50-16.0 pg mL-1 (R2 = 0.9966) with detection limits (LODs) of 2.50, 0.25, and 1.50 pg mL-1 for CRP, TNF-α, and IL-6, respectively. This sensor also demonstrated remarkable selectivity compared to a sensor employing a non-imprinted polymer (NIP), and precision with the highest relative standard deviation (RSD) of 5.14%. The sensor is more accessible compared to prior methods relying on expensive reagents and instruments and complex fabrication methods. Furthermore, the assay provided notable accuracy for monitoring these biomarkers in various human samples with recovery percentages ranging between 99.22% and 103.58%. By integrating microfluidic systems, nanosensing, and MIPs technology, our developed dPADs hold significant potential as a cost-effective and user-friendly analytical method for point-of-care diagnostics (POC) of cytokine-related disorders. This concept can be further extended to developing diagnostic devices for other biomarkers.


Assuntos
Impressão Molecular , Pontos Quânticos , Humanos , Polímeros Molecularmente Impressos , Carbono , Citocinas , Interleucina-6 , Fator de Necrose Tumoral alfa , Limite de Detecção , Impressão Molecular/métodos , Biomarcadores , Corantes Fluorescentes
16.
J Chromatogr A ; 1720: 464775, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38452559

RESUMO

The contents of target substances in biological samples are usually at low concentration levels, and the matrix of biological samples is usually complex. Sample preparation is considered a very critical step in bioanalysis. At present, the utilization of microextraction sampling technology has gained considerable prevalence in the realm of biological analysis. The key developments in this field focus on the efficient microextraction media and the miniaturization and automation of adaptable sample preparation methods currently. In this review, the recent progress on the microextraction sampling technologies for bioanalysis has been introduced from point of view of the preparation of microextraction media and the microextraction sampling strategies. The advance on the microextraction media was reviewed in detail, mainly including the aptamer-functionalized materials, molecularly imprinted polymers, carbon-based materials, metal-organic frameworks, covalent organic frameworks, etc. The advance on the microextraction sampling technologies was summarized mainly based on in-vivo sampling, in-vitro sampling and microdialysis technologies. Moreover, the current challenges and perspective on the future trends of microextraction sampling technologies for bioanalysis were briefly discussed.


Assuntos
Microextração em Fase Sólida , Manejo de Espécimes , Microextração em Fase Sólida/métodos , Tecnologia , Polímeros Molecularmente Impressos , Automação
17.
ACS Sens ; 9(3): 1611-1619, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38471116

RESUMO

Drug detection in biological solutions is essential in studying the pharmacokinetics of the body. Electrochemical detection is an accurate and rapid method, but measuring multiple drugs that react at similar potentials is challenging. Herein, we developed an electrochemical sensor using a boron-doped diamond (BDD) electrode modified with a molecularly imprinted polymer (MIP) to provide specificity in drug sensing. The MIP is a polymer material designed to recognize and capture template molecules, enabling the selective detection of target molecules. In this study, we selected the anticancer drug doxorubicin (DOX) as the template molecule. In the electrochemical measurements using an unmodified BDD, the DOX reduction was observed at approximately -0.5 V (vs Ag/AgCl). Other drugs, i.e., mitomycin C or clonazepam (CZP), also underwent a reduction reaction at a similar potential to that of DOX, when using the unmodified BDD, which rendered the accurate quantification of DOX in a mixture challenging. Similar measurements conducted in PBS using the MIP-BDD only resulted in a DOX reduction current, with no reduction reaction observed in the presence of mitomycin C and CZP. These results suggest that the MIP, whose template molecule is DOX, inhibits the reduction of other drugs on the electrode surface. Selective DOX measurement using the MIP-BDD was also possible in human plasma, and the respective limits of detection of DOX in PBS and human plasma were 32.10 and 16.61 nM. The MIP-BDD was durable for use in six repeated measurements, and MIP-BDD may be applicable as an electrochemical sensor for application in therapeutic drug monitoring.


Assuntos
Técnicas Eletroquímicas , Polímeros Molecularmente Impressos , Humanos , Técnicas Eletroquímicas/métodos , Boro/química , Mitomicina , Limite de Detecção , Eletrodos , Doxorrubicina
18.
Mikrochim Acta ; 191(4): 186, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451316

RESUMO

A carbon dot (CD) was prepared by o-phenylenediamine and water, which showed bright yellow fluorescence under ultraviolet light irradiation (λ = 580 nm), and verified good fluorescence quenching effect on penicillin G sodium (Png-Na). Using methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, and Png-Na as a template, a kind of composite microsphere combining CD and molecularly imprinted polymer (MIP) was synthesized by surface-initiated atomic transfer radical polymerization (SI-ATRP). For reasons of comparison, we also prepared MIP without CD and non-imprinted polymers (NIPs). Through static and dynamic adsorption experiments, the maximum adsorption capacity was 47.05 mg g-1 and the equilibrium time was 30 min. High-performance liquid chromatography (HPLC) was utilized to determine the content of Png-Na in the spiked milk samples. A sensitive, rapid, and simple method for determination of Png-Na in food samples was developed. The utilized approach enabled the quantification of Png-Na within the concentration range 20-1000 µg L-1 (with a limit of detection of 5 µg L-1). The recoveries achieved were in the range 93.3-98.2%, with a relative standard deviation of 1.2-4.2%. The results demonstrated that CD@MIP possessed the capability of specific adsorption and fluorescence detection of Png-Na, enabling simultaneous detection and enrichment of Png-Na in real samples.


Assuntos
Leite , Polímeros Molecularmente Impressos , Animais , Adsorção , Penicilina G , Carbono
19.
J Chromatogr A ; 1720: 464809, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38490141

RESUMO

An ultrafast, efficient, and eco-friendly method combining magnetic solid phase extraction and capillary electrophoresis with diode array detection have been developed to determine ractopamine residues in food samples. A restricted access material based on magnetic and mesoporous molecularly imprinted polymer has been properly synthesized and characterized, demonstrating excellent selectivity and high adsorbent capacity. Short-end injection capillary electrophoresis method was optimized: 75 mM triethylamine pH 7 as BGE, -20 kV, 50 mbar by hydrodynamic injection during 8 s, and capillary temperature at 25 °C; reaching ultrafast ractopamine analysis (∼0.6 min) with good peak asymmetry, and free from interfering and/or baseline noise. After sample preparation optimization, the conditions were: 1000 µL of sample at pH 6, 20 mg of adsorbent, stirring time of 120 s, 250 µL of ultrapure water as washing solvent, 1000 µL of methanol: acetic acid (7: 3, v/v) as eluent, and the adsorbent can be reused four times. In these conditions, the analytical method showed recoveries around to 100 %, linearity ranged from 9.74 to 974.0 µg kg-1, correlation coefficient (r) ≥ 0,99 in addition to adequate precision, accuracy, and robustness. After proper validation, the method was successfully applied in the analysis ractopamine residues in bovine milk and bovine and porcine muscle.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Fenetilaminas , Animais , Suínos , Extração em Fase Sólida/métodos , Eletroforese Capilar/métodos , Fenômenos Magnéticos , Impressão Molecular/métodos , Cromatografia Líquida de Alta Pressão/métodos
20.
J Chromatogr A ; 1720: 464783, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38492290

RESUMO

This study proposes a new alternative for template removal from molecularly imprinted polymers by heat activated persulfate. It is known that trace amounts of template molecule remains in the polymer network after extraction by current methodologies leading to bleeding and incomplete removal of template which could compromise final determination of target analytes especially in trace analysis. A previously developed molecularly imprinted polymer specially designed for Coenzyme Q10 (CoQ10) extraction was employed as a model to test this template elimination approach. This polymer is based on methacrylic acid and ethylene glycol dimethylacrylate as monomers and Coenzyme Q0 as template. This coenzyme has the same quinone group as the CoQ10. Selectivity was analyzed comparing the recovery of CoQ10 and ubichromenol, a CoQ10 related substance. Chemical degradation using heat-activated persulfate allows the elimination of the template molecule with a high level of efficiency, being a simple and ecological methodology, yielding a polymer that exhibits comparable selectivity and imprinting effect with respect to traditional extraction methods.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Ubiquinona , Temperatura Alta , Polímeros/química , Impressão Molecular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...